Level (Fixed Measuring Points - 5‐point Sensor)
Warning Tank Overfilled
If the measuring point Tank overfilled is reached or exceeded for longer than
5 seconds, a warning is triggered.
Automatic Reset
When the level falls below the measuring point.
Warning Tank Level Low
When the level falls below the measuring point Tank level low for longer than
five seconds, a warning is triggered.
Automatic Reset
When the measuring point is reached.
Fault Tank Empty
When the level falls below the measuring point Tank empty for longer than
five seconds, a fault is triggered.
Automatic Reset
When the measuring point is reached.
Fault Level Sensor Defective
The level sensor transmits a faulty signal for longer than five seconds.
Fault Level Sensor Failure
Triggered when a wire breaks.
Automatic Reset
After replacement of the defective sensor.