Overtemperature shutdown
Standby value ° C
Overtemperature warning
Undertemperature warning
Undertemperature fault
50
5
10
Grid
° C
5
° C
° C
° C
20
° C
Overtemperature fault
10
Fig. 4‐26
T2
Operation
4‐32
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Temperature Parameters (contd.)
Grid
Parameters (Screen 1: Alarm Values)
NOTE: The temperatures in this screen are differential values.
Standby temperature
=
Setpoint temperature - Standby value
The minimum standby temperature is 40°C (100°F), even if the selected
settings would (mathematically) permit the standby temperature to be lower.
Standby value: 50°C (90°F)
The values* are not a factor of the setpoint during the heatup and cooling
phases (Refer to Monitoring of Heatup and Cooling).
When the ALL, ALL HOSES and ALL GUNS groups are used, the values for
warning and fault are always assumed together, even if only one of the
values has been changed. This ensures that the fault value is always larger
than or equal to the value for the respective warning.
Warning
Overtemperature
=
Setpoint temperature + Overtemperature warning
delta*
Warning
Undertemperature
=
Setpoint temperature - Undertemperature
warning delta*
NOTE: The warning value is a factor of the fault value in that the values for
the warning may not be larger than the corresponding values for the faults.
When appropriate, first increase the fault value.
Overtemperature/undertemperature warning: 5°C (10°F)
Fault
Overtemperature
=
Setpoint temperature + Overtemperature fault
delta*
Fault
Undertemperature
=
Setpoint temperature - Undertemperature fault
delta*
Overtemperature/undertemperature fault: 10°C (18°F)