Status display
0 500 h
h500
Remaining time until system
ready
0 20 min
min3
Heating hours until next
maintenance
0 500 h
h500
Heatup phase
Time until automatic enter standby after motor
stop
015 min
min13
0 500 h
h500
System ready
Time until automatic enter standby after motor
stop
015 min
min13
0 500 h
h500
Startup protection
Time until manual standby duration expires
010 min
min9
0 500 h
h500
Standby
Heaters off
Heating hours until next
maintenance
Heating hours until next
maintenance
Heating hours until next
maintenance
Heating hours until next
maintenance
Operation
4‐5
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Status Display
Another screen is called up by touching the line Status display. The contents
of the screen is a factor of the displayed status:
Heatup phase
System ready
Startup protection
Standby
Heaters off, motor running or pressure build-up completed.
By status
Warning
Fault
Shutdown
occurs, the system moves directly to the screen Alarm log (Refer to Fig.
4‐34), where the alarm is indicated.
NOTE: This will not work if the screen saver is active (Refer to Fig. 4‐21).