-XS5
Installation
3‐13
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Interface Key-to-line
Software version <V5.02.004: In the field bus‐based control modes Field bus
and Dual (option Field bus communication), the line speed signals via this
interface are deactivated.
One Line Speed Signal Input for all Motors (XS5)
The connection shown as an example applies to encoders supplied by
Nordson.
P/N
Description
772050 Encoder 500 pulses/revolution, ∅ 10 mm
772051 Encoder 500 pulses/revolution, ∅ 3/8 in
772052 Cable, 9 m (30 ft)
772054 Cable, 18 m (60 ft)
XS5
Connection example
Cable
P/N 772052
Encoder
P/N 772050
P/N 772051
Pin Input Function Pin Pin Function
1 - (Ground) Analog input
2 0 to 10 V or
0 to 20 mA*) or
4 to 20 mA*)
3 + 24 V
DC
Frequency Input POWER+V D POWER+V
4 - (Ground) COM, SHIELD F, G COM, CASE
5 0 to 100 kHz SIGNAL A A SIG. A
Pin 6 not assigned
* Refer to Key-to-line: Selecting Line Speed Voltage or Line Speed Current on I/O Board
Separate Line Speed Signal Inputs (XS5.1, XS5.2)
XS5.n (3‐pin)
Pin Input Function
1 - (Ground) Analog input
2 0 to 10 V
DC
Pin 3 not assigned