Maintenance
5‐4
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Preventive Maintenance (contd.)
Melter part
Activity Interval Refer to page
Filling valve (option) Check control module
detection hole; replace
complete control module
if necessary
When excess material seeps out
of detection hole
(seals in inside worn)
5‐23
Level and overflow
protection evaluators
Calibrate When evaluator or level sensor is
replaced
When the material is changed or
the processing temperature
changes by more than 30 °C (54
°F)
Section Repair
Safety valve for
pneumatics
Performance check;
clean or replace if
necessary
Every six months 5‐24
External Cleaning
External cleaning prevents impurities created during production from causing
the melter to malfunction.
CAUTION: Observe the melter's Degree of Protection when cleaning (Refer
to section Technical Data).
CAUTION: Do not damage or remove safety labels. Damaged or removed
safety labels must be replaced by new ones.
Remove material residue only with a cleaning agent recommended by the
material manufacturer. Heat with an air heater if necessary.
Remove dust, flakes etc. with a vacuum cleaner or a soft cloth.
Nordson recommends the cleaning agent P/N 771192 - CLEANER C,
12 spray bottles, 0.5 liter each. Observe material safety data sheet!
Control Panel
CAUTION: Set Screen cleaning. This ensures that no functions are
unintentionally triggered by touching the screen.
Clean the insides of the plastic frame on the control panel front regularly with
a damp, soft cloth. Use caution to ensure that the surface is not scratched or
scoured, particularly when removing hard residue and abrasive dust. Do not
allow solvents to come into contact with the control panel front; solvents
could corrode the plastic frame.