Profibus address
10
Control
panel
Standard I/O
No Profibus
Fig. 4‐69
Profibus
Control
panel
Standard I/O
No field bus
Fig. 4‐70
ControlNet or EtherNet/IP
Control
panel
Standard I/O
No field bus
Fig. 4‐71
Operation
4‐57
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Melter (contd.)
Profibus Setup (or One of the Other Field Buses)
The melters on the field bus each require an address for communication;
each address may be assigned only once in the entire field bus.
Profibus: The address is set on the IPC (Refer to Fig. 4‐69).
10
ControlNet: The address is set with two decimal dials on the gateway
located in the electrical cabinet.
EtherNet/IP: The IP address can be set either with the DIP switches on the
gateway or via a PC.
Profinet IO: The IP address can be set on a PC:
Refer to the separate field bus document for more information.
Refer to section Troubleshooting / Checking Transmitted Field Bus
Data.
Selecting the Control Mode
NOTE: The control mode can be changed only on the control panel.
The option Field bus communication offers several control modes, Refer to
Control Modes on the next page.
The illustrations 4‐72 to 4‐78 show the keys that must be touched to set the
desired control mode.
Standard
Software version V5.02.004 and higher: In the field bus‐based control
modes the source for the line speed signal (XS5 or field bus) can be selected
(Fig. 4‐94 M2).