Temperature unit:
° C
Pressure unit:
bar
Fig. 4‐60
V15
Automatic heatup upon
melter start
Maximum temperature setpoint
200
Fig. 4‐61
System ready delay time
min
0
Fig. 4‐62
V17
Operation
4‐53
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Melter (contd.)
Either°C or°F can be selected as the temperature unit.
°C
Either bar, psi or kPa can be selected as the pressure unit.
bar
Maximum Temperature Setpoint
This parameter is used to adapt the melter to the maximum material
processing temperature permitted.
Setting range
Standard melter 40 to 230°C 100 to 450°F
High temperature
melter
40 to 250°C 100 to 480°F
Automatic heatup upon melter start / automatic heatup upon melter
start blocked
Software Version 6.00.000 and higher. Refer to Daily Startup.
System Ready Setup
The system ready delay time is the time after which all components have
reached their setpoint temperatures (A) and before the system indicates
readiness (B). This additional time allows the material to reach a thermally
homogenous state.
System ready
delay time
Time
Temperature
(A) (B)
The system ready delay time, if activated, runs after every Heatup phase
(status display).
0 min