EasyManua.ls Logo

Nordson VersaBlue VA - Page 198

Nordson VersaBlue VA
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
+V
‐V
E1
E2
E3
E4
E6
E7
E8
E5
+V
E9
+V
E10
+V
E11
E12
+V
+24 V
DC
0 V
DC
24 V
DC
external
A7
A8
A9
A10
A11
A12
A6
A5
A4
A3
A2
A1
+24 V
DC
0 V
DC
0 V
DC
0 V
DC
0 V
DC
+24 V
DC
0 V
DC
Troubleshooting
6‐24
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
LEDs and Plugs of I/O Board (contd.)
Plug
LED Inputs (LED lit, if 24 V
DC
supplied)
X9.3 E1 Heaters on
X9.4 E2 All motors ON (collective enable)
X9.5 E3 Enable Motor 1
X9.6 E4 Enable Motor 2
X9.7 E5 Enter standby
X9.8 E6 Key-to-line mode on
X9.9 E7 Application group 1
X9.10 E8 Application group 2
X13.2 E9 Application group 3
X13.4 E10 Application group 4
X13.6 E11 Main switch (main contactor)
X13.8 E12 Reserved
NOTE: The LED indicates only that there is voltage at the I/O board input; it
does not indicate whether the function is activated
Plug
LED Outputs (LED lit)
X3.3 A1 Light tower: Green lamp System ready
X3.4 A2 Light tower: Yellow lamp Warning
X3.5 A3 Light tower: Red lamp Fault
X6.1 A4 Main contactor
X7.1 A5 Inert gas control (solenoid valve)
X8.1 A6 Pressure build‐up completed
X11.2 A7 System ready
X11.3 A8 General alarm -warning-
X11.4 A9 General alarm -fault-
X11.5 A10 Reserved
X12.1
A11 Fill tank
(signal to interface XS2)
X12.2
X12.3
A12 Fill tank
(signal to interface XS3)
X12.4
Refer to the section Installation, Interface Standard I/O for information on the
signals at XS2.

Table of Contents