118 Chapter 9 Replacing media drives
CAUTION
Use an ESD wrist strap to protect static-sensitive components.
Step Action
1
Prepare the server for floppy disk drive replacement as follows:
a. Shut down the server, and then disconnect the power and
peripheral device cables.
b. Remove the side cover.
c. Remove the upper fan holder foam.
For instructions, see "Preparing the server for hardware
maintenance" (page 81).
WARNING
Failure to follow the procedures in "Preparing the
server for hardware maintenance" (page 81) can
result in electrical shock or equipment damage.
2
Disconnect the power and signal cables of the disk drive.
3
Open the front panel on the server.
4
Remove and save the two screws that secure the floppy disk drive to
the front of the chassis.
5
Slide the assembly toward the back of the server to disengage it
from the tabs that secure the carrier assembly to the server.
6
Remove the assembly from the chassis.
7
Remove the four screws that hold the bracket to the drive, and set
them and the bracket aside.
8
Place the drive in an antistatic protective wrapper.
9 Continue with "To install a replacement floppy disk drive" (page 119).
—End—
Nortel CallPilot
703t Server Maintenance and Diagnostics
NN44200-702 01.03 Standard
5.0 3 April 2007
Copyright © 2007, Nortel Networks Nortel Networks Confidential
.