130 Chapter 10 RAID operations
Step Action
1
To load the MegaRAID console, click Start Programs Power
Console Plus Launch Client.
Note: Ensure that Access Mode Full Access is selected.
2
Click OK.
Result: Result: the MegaRAID Power Console Plus window
appears.
3
Ensure all drives are in ONLINE state (marked GREEN).
4
In the Physical Devices section, right-click the Channel-2 hard disk
drive. Example: Channel-2 (0) A1-2-Onln.
5
Select Tools Fail Drive from the pop-up menu.
Result: A message appears advising that marking the Online drive
Failed results in changes.
6
Ignore the warning and click OK. The drive status will change to
FAILED and the color of the icon will change to RED. Example:
Channel-2 (0) A1-2-Failed.
Result: The audible alarm should start beeping.
—End—
ATTENTION
The alarm can be silenced, but under no circumstances should it be disabled.
Select Adapter Alarm Control Silence Alarm.
At this point, the RAID is split, and the drive marked FAILED is the backup
drive and will no longer be written to. A release upgrade or PEP installation
can now be completed without impact to the backup’ drive.
Nortel CallPilot
703t Server Maintenance and Diagnostics
NN44200-702 01.03 Standard
5.0 3 April 2007