12-6 Cabinet maintenance operations
AccessNode 323-3001-210 Issue 1.0
Procedure 12-1
Replacing the batteries
Use this procedure to replace batteries in an S800A cabinet that is currently
carrying traffic.
If the batteries that are to be replaced are installed in a new installation or in a
cabinet that is not in-service, see Chapter 9, “Installing and connecting the
batteries” for battery installation.
Battery strings 1-12 will provide at least eight hours of battery back-up for a
fully configured S800A system. Battery strings 13 and 14 may be used to
provide additional battery back-up power.
The batteries require replacement:
when an LVA alarm is generated significantly early (prior to eight hours)
in the battery back-up mode
during battery maintenance activities when the battery voltage is checked
and deemed to low
as listed in the battery manufacturer’s maintenance requirements
Requirements
The S800A system must be operating normally on rectifier power.
Test sets
A voltmeter RMS Fluke 8050A (or equivalent) test set is needed.
Tools required
A screwdriver, slotted, small (0.1-inch width) is required.
Documentation references
See NTP 169-2071-500.
—continued—

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortel SONET AccessNode 800A Series and is the answer not in the manual?

Nortel SONET AccessNode 800A Series Specifications

General IconGeneral
BrandNortel
ModelSONET AccessNode 800A Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals