4-2 Installing the OSP cables
AccessNode 323-3001-210 Issue 1.0
Prerequisites for installation
The prerequisites for bonding and grounding the OSP cabling include:
The cabinet has been mounted on the selected concrete pad as defined in
Chapters 1, 2 and 3 of this practice.
All hardware and materials are available and have been checked for
completeness and readiness for the installation.
All the required drawings, local installation instructions, job
specifications, and other documentation are available and ready for use.
encapsulating material as per Bell System Practices Section
631-600-305 Issue 1, November 1972 or the procedure enclosed in the
8962 Multi-mold package
electrical tape
cable insulating gel removal material; D-gel or equivalent de-greaser
1/2-inch trade size split flex tubing or equivalent
fiber optic protective buffer tubing or equivalent
Precautions
The following safety precautions should be observed at all times during the
OSP cable bonding and grounding procedures:
No equipment should be installed until the cabinet is firmly secured to its
mounting pad, as described in Chapter 2, “Installing the cabinet”.
Do not open the front or rear doors unless the cabinet is firmly secured to
the mounting pad.
Observe all National Electrical Code (NEC) and local codes for electrical
wiring.
CAUTION
Electrical shock hazard
The procedures listed in this chart should be done by a
qualified electrician. The procedures in this chapter are
recommended guidelines; be sure to follow all local codes
for wiring procedures.