5. MAINTENANCE MENUS
The following message appears when a test pattern is printed.
P=***
W=***
P: Number of test-print pages (Unit: sheets)
W: Belt temperature wait time (Unit: seconds)
The displays are switched to the following by pressing the MENU
or
MENU
button.
U=***[###] H=XXX
L=***[###] s=XXX
U: *** = Center thermistor target temperature [Unit: ˚C]
[###] = Center thermistor current temperature [Unit: ˚C]
H: XXX= Heater thermistor current temperature [Unit: ˚C]
L : *** = Lower thermistor target temperature [Unit: ˚C] (Not used)
[###] = Lower thermistor target temperature [Unit: ˚C] (Not used)
S: XXX= Site thermistor current temperature [Unit: ˚C]
t=***
H=***%
T: A measured environment temperature [Unit: ˚C]
H: A measured environment humidity [Unit: %]
s1tR=*.** s2tR=*.**
s3tR=*.** s4tR=*.**
S1TR: Station1 Transfer low-voltage setting value] Unit: KV]
S2TR: Station2 Transfer low-voltage setting value] Unit: KV]
S3TR: Station3 Transfer low-voltage setting value] Unit: KV]
S4TR: Station4 Transfer low-voltage setting value] Unit: KV]
s5tR=*.**
S5TR: Station5 Transfer low-voltage setting value] Unit: KV]
s1R=*.** s2R=*.**
s3R=*.** s4R=*.**
S1R: Station1 Transfer current value [Unit: uA]
S2R: Station2 Transfer current value [Unit: uA]
S3R: Station3 Transfer current value [Unit: uA]
S4R: Station4 Transfer current value [Unit: uA]
s5R=*.**
S5R: Station5 Transfer current value [Unit: uA]
etMP=***UtMP=***
Reg=****eXt=***
ETMP: A parameter for correction of constant hopping motor speed (an
environmental temperature) [Unit: DEC].
UTMP: A parameter for correction of constant fuser motor speed (a target
fusing temperature) [Unit: DEC].
REG: A hopping motor constant-speed timer value (a set input/output value)
[Unit: HEX].
EXT: A fuser motor constant-speed timer value (a set input/output value) [Unit:
HEX].
iD=**** BLt=****
LVtH=xxx(***)
ID: ID motor constant-speed timer value (I/O set value) [Unit: HEX]
BLT: Belt motor constant-speed timer value (I/O set value) [Unit: HEX]
LVTH: [xxx] = Low-voltage power temperature [Unit: ˚C]
(***) = Low-voltage power thermistor scanning AD value [Unit: HEX]