Tray1 IN1 sensor
DUPLEX front sensor
Tray1 paper end sensor
Tray1 paper near end sensor
Tray2 IN1 sensor
Tray2 paper end sensor
Tray2 paper near end sensor
Tray3 IN1 sensor
Tray3 paper end sensor
Tray3 paper near end sensor
Tray4 IN1 sensor
Tray4 paper end sensor
Tray4 paper near end sensor
Tray5 IN1 sensor
Tray5 paper end sensor
Tray5 paper near end sensor
IN3 sensor
Sag sensor
Figure 5-1-1 Switch sensor locations (Paper sensor)
5.3.2.3 Switch scan test
The switch scan test is used for checking IN sensors and switches.
1. Enter the self-diagnostic mode (level 1) and, until “SWITCH SCAN” appears
on the upper display, press the MENU
or MENU button (the MENU button
displays the next test option and the MENU
button displays the preceding test
option). Then press the OK button.
sWitcH scan
2. Press the MENU or MENU button until an option shown in table 5-3 for the
unit to test appears on the lower display (the MENU
button displays the next
option and the MENU
button displays the preceding option).
3. Press the OK button. The switch scan test starts, the unit’s name and current
status being displayed
in1 in2 in3 Fin
1=H 2=L 3=H 4=L
Operate the unit (figure 5-1/5-2). Display information on applicable LCD display
(the information displayed vary depending on the sensor.Refer to table 5-3.)
4. Press the CANCEL button to return to the state in step2.
5. Repeat steps 2 through 4 when necessary.