75
Commands and Responses Section 5-9
5-9-2 Read Setting Data
Command
This command reads setting data. If the number of elements is set between
“2” and “6”, consecutive address setting data can be read.
Refer to
5-10 Variable Area Map for information on specifying variable types
and addresses.
This command can be used in either setting area 0 or 1.
Response
Response code: The code shown above represents normal completion. For
details on the response code, refer to
5-5 Read from Variable Area.
Variable
type
Address Setting data
ch Description
“C1” “0000” to “0019” 1 Setting data for setting area 0
“0100” to “0119” 2
“C3” “0000” to “003E” 1 Setting data for setting area 1
“0100” to “013E” 2
“C5” “0000” 1 Setting data for setting area 0
“0100” 2
“C7” “0000” to “0001” 1 Setting data for setting area 1
“0100” to “0101” 2
MRC SRC
Variable
type Address
Bit
position
No. of
elements
“01” “01” “00” “0001”
MRC SRC
Response code
“01” “01” “0000” Status
Data