7-28 Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
ISO/IEC 16022 Symbol Quality Output 1
Output on Axial Non-Uniformity
Output on Unused Error Correction
Symbol Contrast Threshold
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, toggles Output 1 to an active state when Axial Non-Uniformity
Threshold is met.
Serial Cmd: <K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,
output on axial non-uniformity
,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, toggles Output 1 to an active state when UEC Threshold is
met.
Serial Cmd: <K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Lets the user set the acceptable level of symbol quality.
Definition: Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K800,
output on symbol contrast,
symbol contrast threshold
,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Grade C
Options: 0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D