Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 7-29
I/O Parameters
Print Growth Threshold
Axial Non-Uniformity Threshold
Unused Error Correction Threshold
Usage: Lets the user set the acceptable level of symbol quality.
Definition: Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd: <K800,output on symbol contrast,symbol contrast threshold,output on print
growth,
print growth threshold
,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Grade C
Options: 0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D
Usage: Lets the user set the acceptable level of symbol quality.
Definition: Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd: <K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,
axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Grade C
Options: 0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D
Usage: Lets the user set the acceptable level of symbol quality.
Definition: Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd: <K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Grade C
Options: 0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D