9 Preservation
9.1 Cleaning 103
9.1.1 Using high pressure washer 103
9.2 Storage 103
9.2.1 Long time storage 103
9.2.2 Oil filling in the grease lubrication storage 103
9.1 CLEANING
9.1.1 Using high pressure washer
The compactor can be cleaned with a high pressure washer. Avoid directing the beam towards any elec-
trical connections and components.
IMPORTANT: Use hearing protection when cleaning the compactor with a high pressure washer.
9.2 STORAGE
A thorough cleaning and a complete lubrication is recommended prior to long term storage. The control
unit must be kept warm and dry to ensure functionality. The control unit may be detached from the com-
pactor and stored inside during the storage period. Touch-up paint is recommended to avoid corrosion.
9.2.1 Long time storage
If youre using grease of NLGI class 2 with EP additives (extreme pressure) theres no need for special pre-
cautions to be made regarding long time or winter storage. Perform a complete lubrication service on the
machine before storage. If youre using a grease type according to lubrication standards, but not having
the anti-corrosion effect, the system must be filled up with anti-corrosive oil. Regular motor oil is suf-
ficient.
9.2.2 Oil filling in the grease lubrication storage
This operation is easily done with an empty grease gun filled up with motor oil. Remove the piston and the
coil spring in the gun. Insert an empty grease cartridge and fill the grease gun while holding it vertically.
Attach the gun at the inlet on the main distributor and empty the gun into the system (1/2 litre).