EasyManua.ls Logo

ORKEL MP2000-X - Frame, Drawbar, Attachments; Frame; Main Components, Fastening Points; Chamber Roller Bushings

ORKEL MP2000-X
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.11 FRAME, DRAWBAR, ATTACHMENTS
7.11.1 Frame
Check the welding for cracks or deformations once a month.
7.11.2 Main components, fastening points
Check all major bolt connections and re-tighten if necessary.
l Drawbar—frame
l Drawbar—eye
l Chamber—frame
l Feed hopper—frame
l Elevator—frame
Pay extra attention to the bolts fixing the draw bar and eye. (574 Nm)
Figure 7.30 :
Fixing bolts for drawbar eye
7.12 CHAMBER ROLLER BUSHINGS
IMPORTANT: The bushings must be controlled every 5000 bales produced, or when 1000 hours of operation are
reached. Whatever comes first.
IMPORTANT: The distributed load to the bearings will not be even, and therefore the wear is not evenly dis-
tributed inside the bearing.
7.12.1 Wear inspection
A quick control of the degree of wear (clearance) might be done with a crowbar and a dial gauge. If no
excessive wear is found, theres no need for further dismantling of the bushings.
7 MAINTENANCE AND MECHANICAL ADJUSTMENTS 84

Table of Contents