4. Activate the function greaser from the control box once more (the pump will run as long as the but-
ton on the control box is activated).
5. Disconnect the tube from the first distributor block and activate the pump until you have a constant
flow from this outlet.
8.3 ELECTRIC PUMP AND MAIN DISTRIBUTOR
8.4 TROUBLESHOOTING FOR BEKA MAX
Problems Cause Remedy
Pump does not
work
Fuse defective
Problem with the power supply
Problem with pump motor
Replace fuse
Replace electrical cable
Replace pump motor
8 LUBRICATION 96