14-26
Address
FP0 T32
FP0 C10,
C14, C16,
C32, SL1
Name Descriptions
DT90059 DT9059
Serial communication
error code
- Tool port
bit 0=1: Over run error
bit 1=1: Framing error
bit 2=1: Parity error
- RS232C port
bit 8=1: Over run error
bit 9=1: Framing error
bit 10=1: Parity error
DT90060 DT9060
Process
number:
0 to 15
DT90061 DT9061
Process
number:
16 to 31
DT90062 DT9062
Process
number:
32 to 47
DT90063 DT9063
Process
number:
48 to 63
DT90064 DT9064
Process
number:
64 to 79
DT90065 DT9065
Process
number:
80 to 95
DT90066 DT9066
Process
number:
96 to 111
DT90067 DT9067
Step
ladder
process
Process
number:
112 to 127
Indicates the startup condition of the step ladder
process. When the process starts up, the bit
corresponding to the process number turns
on”1”.
Monitor using binary display.
A programming tool software can be used to
write data.