EasyManua.ls Logo

Panasonic KX-TD500 - End of Pulsing (End of Identification) Signal; Tenant Select Mode for DID; DDI; Alert Ringing

Panasonic KX-TD500
392 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System
118 Programming Guide
Parameter 62. End of Pulsing (End of Identification) Signal
Default None
Value Range
1. None
2. 1-15
Description/Function Specifies the pulse dialling signal after the inter-digit timer expires.
(Assignable only when "DR2" is specified in "Channel Type"
programming and "MFC-R2" is specified in "Receiver Type"
programming in Section "1.6 E1 Port Assignment.")
Note
If "None" is specified, the end of pulse dialling signal is not
sent to the Central Office.
Reference None
Parameter 63. Tenant Select Mode for DID / DDI
Default Trunk Group
Value Range
1. Trunk Group
2. DID / DDI No.
Description/Function Specifies whether to enable or disable the tenant assigned on a DID
/ DDI No. basis. If "Trunk Group" is selected, then the tenant no.
works for the CO lines belonging to the Trunk Group.
Reference 9.2 Number Transformation (P/G)
Parameter 65. Alert Ringing
Default Disable
Value Range
1. Disable
2. Enable
Description/Function Specifies whether or not to alert the alert extension when the
extension user does not respond to the Timed Reminder (wake-up
call).
Reference 1.8 Ringing Features (F/G)
Timed Reminder (Wake-Up Call)
Timed Reminder, Remote (Wake-Up Call)
2.7.1 Setting the Alarm (Timed Reminder (Wake-Up Call)) (U/
M)
3.1.1 Setting the Alarm for Other Extensions (Remote Timed
Reminder (Wake-Up Call)) (U/M)
2.2 Tenant (P/G)
Alert Extension Day / Night

Table of Contents