Parameter Command Sequence (1-16)
Default None
Value Range None, S1 - S8, 1T - 4T, TR, RET, OFF
Description/Function The following commands are provided to construct a UCD Time
Table procedure.
<Commands list and their functions>
1. None:
Skips to the next sequence.
2. S1 - S8:
OGM (1-8) is sent to the caller if available. If not, wait until
OGM (1-8) becomes available.
3. 1T - 4T:
Callers are put in the waiting queue for N (1-4) 8 seconds
while hearing the ringback tone or music on hold.
4. TR:
Transfers a call to the Overflow destination.
5. RET:
Returns to the first step of the sequence.
6. OFF:
Disconnects the call compulsorily.
Note
If an unavailable OGM S(1-8) is assigned in the UCD Time
Table, it will be ignored.
Reference 3.3 Extension Group (P/G)
3.5 Incoming Group (P/G)