System
Programming Guide 41
2.2 Tenant
Used to assign various parameters on a tenant (1-8) basis.
Parameter Tenant No.
Default 1
Value Range 1-8
Description/Function Specifies the tenant (1-8) which you are going to programme.
Reference 1.3 System Features (F/G)
Tenant Service
Parameter Operator FDN
Default Blank
Value Range 3-4 digits consisting of 0-9
Description/Function Specifies the FDN (Floating Directory Number) of Extension
Group or Incoming Group. Calls by the feature number for
Operator Call will reach to this destination.
Reference 1.3 System Features (F/G)
Floating Station
1.6 Originating Features (F/G)
Operator Call