Group
142 Programming Guide
Parameter Group Type
Default Group No.126: VM, Group No.127: AA, Group No.128: Operator,
Others: None
Value Range
1. None
2. Terminate
3. Circular
4. Ring
5. Operator
6. VM
7. AA
8. UCD
Description/Function Specifies the Group Type for each Extension Group.
This determines how the Extension Group handles the incoming
calls directed to it.
1. None:
No Group Type is specified.
2. Terminate:
Functions as a Station Hunting Group (Terminate).
3. Circular:
Functions as a Station Hunting Group (Circular).
4. Ring:
Functions as a Ring Group.
5. Operator:
Functions as an Operator Group.
6. VM:
Functions as a VM (Voice Mail) Group.
7.
AA:
Functions as an AA (Automated Attendant) Group.
8.
UCD:
Functions as a UCD (Uniform Call Distribution) Group.
Reference 1.3 System Features (F/G)
Extension Group