Line
178 Programming Guide
Parameter Start Signal Type
Default Wink
Value Range
1. Immediate
2. Wink
Description/Function Specifies the start signal type for a DID trunk and a TIE (E&M) 
trunk.
1. Immediate:
The system sends the dialling digits to CO after waiting for the 
time length determined by "First Dial Timer" in "Card 
Properties" screen of the corresponding trunk card.
 For information on "Card Properties" screen, please refer to 
"Card Type" in Section "1.2 Slot Assignment."
2. Wink:
The system sends the dialling digits to CO after receiving the 
wink signal.
Reference • 3.1 TIE Line Features (F/G)
– TIE Line Service
Parameter Answer Wait Timer
Default None
Value Range
1. None
2. 1 min
3.
2 min
4. 3 min
5. 4 min
Description/Function Specifies the length of time in minutes the system waits, after an 
outgoing CO call is made, before the other party answers the call.
If the call is not answered before this timer expires, the call will be 
disconnected automatically.
(Assignable only when E1 / ELCOT / RCOT / T1 [TIE / DID] / 
DID-2W / DID-MFC / BRI / PRI23 / PRI30 card is installed in the 
system.) 
Reference None