Line
Programming Guide 199
<Key Type Assignment>
The following Key Type Assignment screen is displayed by clicking "Key Type Display"
button (including "Not Stored") for each CO key on the above screen.
<Additional Parameters Required by Key Type>
Depending on a Key Type, additional parameters are required as follows.
Key Type
Additional
Parameters
(default)
Description
SINGLE-CO Trunk Line
No.
Specifies the trunk port physical number (10101 to 31416).
Tone (2) Specifies the ringer frequency (ring tone type: 1-8) for
incoming calls.
GROUP-CO Trunk Group
No.
Specifies the Trunk Group number (01 - 48).
Tone (2) Specifies the ringer frequency (ring tone type: 1-8) for
incoming calls.
LOOP-CO Tone (2) Specifies the ringer frequency (ring tone type: 1-8) for
incoming calls.
DSS EXT. Specifies the extension number ( 3 or 4 digits).
PHANTOM EXT. Specifies the phantom extension number ( 3 or 4 digits).
Ringing (Yes) Specifies whether the extension rings or not when a call to a
phantom button comes in on the extension.