Line
172 Programming Guide
Parameter Name
Default CO001-CO192
Value Range Up to 10 characters consisting of 0-9, A-Z, a-z or the following
marks: ! # $ % ( ) + , - / : ; < = > ? @ &.
Description/Function Specifies the name for the trunk line.
Note
• This is shown on a display PT when receiving a call using
this trunk.
Reference • 1.17 Display Features (F/G)
– Display, Call Information
Parameter Incoming Type
Default (1)DIL: ELCOT / GCOT / LCOT / PCOT / RCOT / T1 [GCO] / T1
[LCO] card (2)DID: DID / DID-2W / DID-MFC / E1 [DR2] / E1
[E&M-C (MFC-R2)] / E1 [E&M-P (MFC-R2)] / T1 [DID] card
(3)TIE: E1 [E& M-C (Pulse, DTMF)] / E1 [E&M-P (Pulse,
DTMF)] / E&M / T1 [TIE] card (4)DDI: BRI / PRI23 / PRI30 card
Value Range
1. DIL
2. DID
3. TIE
4. DDI
5. MSN
Description/Function Specifies how the incoming CO call via this trunk line is routed to
the destination in the system.
1. DIL:
Incoming CO calls are routed by DIL (Direct In Lines) 1:1 or
1:N feature.
2. DID:
Incoming CO calls are routed by DID (Direct Inward Dialling)
feature.
3. TIE:
Incoming CO calls are routed by TIE Line feature.
4. DDI:
Incoming CO calls are routed by ISDN DDI (Direct Dialling In)
feature.
5. MSN:
Incoming CO calls are routed by ISDN MSN (Multiple
Subscriber Number) feature.