4.7 Configuration [1]
344 Feature Guide
Extension Number
Specifies the extension number of the port.
To change the extension number of a wired extension, follow the steps below:
1. Type the new extension number, then click Apply.
2. Set the status of the extension port to "OUS", then "INS".
When changing the extension number, make sure that the extension port is not in use. If the extension
number is changed while the port is in use, the new extension number will not come into effect.
Default
Starting at 101 (For port 01 of the first extension card that is installed. Extension numbers are preset for
subsequent extensions by adding one to the previous extension number.)
Value Range
Max. 4 digits (consisting of 0–9)
Programming References
4.7.14 Extension Port [1-5] Port Command
Feature Guide References
None
Extension Name
Specifies the extension name of the port. As for the available characters, refer to the character code table
described in section 3.2.1 Installing and Starting KX-TDA50 Maintenance Console.
Default
Not stored.
Value Range
Max. 20 characters
Feature Guide References
None
XDP Mode (for S-Hybrid port)
Turns XDP mode on or off for the port.
Default
Off
Value Range
On: XDP enabled (The main telephone and sub telephone have different extension numbers.)
Off: XDP disabled (The main telephone and sub telephone have same extension number [main telephone's
extension number]. = Parallel Mode)