590 Series DC Digital Drive Parameter Specification Tables
C-9
Tag Mn Function Block Name Parameter Name Minimum Maximum Default Units Range Notes
150 e6 MAIN PORT (P1) BAUD RATE 0 9 5 0: 300
1: 600
2: 1200
3: 2400
4: 4800
5: 9600
6: 19200
7: 38400
8: 57600
9: 115200
V0 W0
151 e7 AUX PORT (P2) BAUD RATE 0 9 6 0: 300
1: 600
2: 1200
3: 2400
4: 4800
5: 9600
6: 19200
7: 38400
8: 57600
9: 115200
V0 W0
152 e8 MAIN PORT (P1) ESP SUP.(ASCII) 0 1 0 0: DISABLED
1: ENABLED
V0 W0
153 e9 AUX PORT (P2) ESP SUP.(ASCII) 0 1 0 0: DISABLED
1: ENABLED
V0 W0
155 eb DRIVE INFO VERSION NUMBER 0x0000 0xFFFF 0x0000 V0 W4
158 ee MAIN PORT (P1) ERROR REPORT 0x0000 0xFFFF 0x00C0 V0 W0
159 ef AUX PORT (P2) ERROR REPORT 0x0000 0xFFFF 0x00C0 V0 W0
161 eh SEQUENCING AUX START 0 1 1 0: OFF
1: ON
V0 W0
162 ei CONFIGURE DRIVE LEGACY MODE 0x0000 0xFFFF 0x0001 V1 W2
168 eo SEQUENCING AUX ENABLE 0 1 1 0: OFF
1: ON
V0 W0
169 ep FIELD CONTROL FIELD ENABLED 0 1 0 0: DISABLED
1: ENABLED
V0 W4
170 eq FIELD CONTROL FIELD ENABLE 0 1 1 0: DISABLED
1: ENABLED
V0 W1
171 er FIELD CONTROL SETPOINT 0.00 100.00 100.00 % V1 W0
172 es FIELD CONTROL INT. GAIN 0.00 100.00 1.28 V0 W0
173 et FIELD CONTROL PROP. GAIN 0.00 100.00 0.10 V0 W0
174 eu FIELD CONTROL FLD. WEAK ENABLE 0 1 0 0: DISABLED
1: STANDARD
V0 W1