Service Manual 13 Errors
13.2 Error messages
1/09 PERFECTA 115 / 132 / 168 / 225 – TS 93
PERFECTA Schneidemaschinenwerk GmbH  D-02625 Bautzen  Schäfferstr. 44  Tel.: +49-3591-556-131 to -133  Fax: +49 3591-556-139
13.2 Error messages
Error Message Text Remarks
00 No Error - Call a service technician.
01
Start procedure recognizes a
common error
- Find the definite error cause in the
"Diagnostic" menu.
02
Error control computer -
Permission "Clamping and
cutting" ON
- Call a service technician.
03
Error control computer -
Automat signal ON
- Call a service technician.
04
Error control computer- signal
clamping ON
- Call a service technician.
05
Error left-hand push button
S50 ON
- S50 was actuated upon powering up.
06
Error right-hand push button
S51 ON
- S51 was actuated upon powering up.
07
Error control computer -
signal "Lock the clamp" ON
- Call a service technician.
08
Error control computer-
signal "Full automat start" ON
- Call a service technician.
09
Error control computer- signal
"Full automat start" ON
- Call a service technician.
10
Error stock not free, clamp is
down or S29 problem
- S29 was actuated upon powering up.
11
Error Pressure signal, flow
switch S60 or contactor K64
ON
- S60/K64 was actuated upon powering up.
12 Error Light guard not free
- The light guard was actuated upon
powering up.
20 Common operating error
- Find the definite error cause in the
"Diagnostic" menu.
21
Error Cutting contactor K50
not OFF
- Cut contactor K50 does not switch off.
22
Error Cutting contactor K50
not ON
- Cut contactor K50 does not switch on.
23
Error Cutting contactor K51
not OFF
- Cut contactor K51 does not switch off.
24
Error Cutting contactor K51
not ON
- Cut contactor K51 does not switch on.
25
Error Clamping contactor K60
not OFF
- Clamp contactor K60 does not switch off.
26
Error Clamping contactor K60
not ON
- Clamp contactor K60 does not switch on.
27
Error Clamping contactor K61
not OFF
- Clamp contactor K61 does not switch off.
28
Error Clamping contactor K61
not ON
- Clamp contactor K61 does not switch on.
29
Error Flow switch S60 or
contactor K64 (B60 valve
monitoring) doesn't switch
OFF
- Monitoring sensor B60 does not switch off.