Error Message Text Remarks
84
Error of the safety module,
voltage of 5 Volt DC for CPU
2 out of tolerance
- Call a service technician.
- Turn off the machine.
Replace the safety module.
85
Error of the safety module,
voltage of 3 Volt DC for CPU
1 out of tolerance
- Call a service technician.
- Turn off the machine.
Replace the safety module.
86
Error of the safety module,
voltage of 3 Volt DC for CPU
2 out of tolerance
- Call a service technician.
- Turn off the machine.
Replace the safety module.
87
Error of the safety module,
dynamic comparison test of
ROM for CPU 1 failed
- Call a service technician.
- Turn off the machine.
Replace the safety module.
88
Error of the safety module,
dynamic comparison test of
ROM for CPU 2 failed
- Call a service technician.
- Turn off the machine.
Replace the safety module.
89
Error of the safety module,
different values between
ROM CPU 1 and CPU 2
- Call a service technician.
- Turn off the machine.
Replace the safety module.
90
Error of the safety module,
dynamic test of RAM for
CPU 1 failed
- Call a service technician.
- Turn off the machine.
Replace the safety module.
91
Error of the safety module,
dynamic test of RAM for
CPU 1 failed
- Call a service technician.
- Turn off the machine.
Replace the safety module.
92
Error analogue digital con-
verter CPU 1
- Call a service technician.
- Turn off the machine.
Replace the safety module.
93
Error analogue digital con-
verter CPU 2
- Call a service technician.
- Turn off the machine.
Replace the safety module.
94
Instruction test of CPU 1
failed
- Call a service technician.
- Turn off the machine.
Replace the safety module.
95
Instruction test of CPU 2
failed
- Call a service technician.
- Turn off the machine.
Replace the safety module.