LUBRICATION SYSTEM 19
4 Loosely assemble the bracket of the suction pipe
to the correct main bearing cap. Fit the suction pipe
to the oil pump together with a new joint or an "O"
ring. Tighten the setscrews. Tighten the setscrew of
the suction pipe bracket. If the clamp type bracket,
used on some four cylinder engines, has been
removed, ensure that the clamp, the bracket and
the pipe are correctly aligned before the setscrews
are tightened. Ensure that there is no stress on the
suction pipe.
5Fit the sump, operation 19A-03, and fill it with an
approved oil to the "MAX" level on the dipstick.
To inspect and to correct19A-05
1 Wash the assembly in an approved cleaning fluid
and dry it thoroughly.
2 Check the pipe, the strainer and the welded
joints for cracks and other damage. Check that the
mounting bracket is secure.
3 If the damaged component cannot be welded
correctly, renew the assembly.
4 Composite material parts must be renewed if
they have cracks or damage.
Perkins Phaser/1000 Series, April 1995 19A.09