20A FUEL SYSTEM
Data and dimensions
Fuel lift pump - four cylinder engines
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.C.Delco, type XD
Method of drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eccentric on camshaft of engine
Static pressure (no delivery) . . . . . . . . . . . . . . . . . . . . . . . . . . 42/70 kPa (6/10 lbf/in
2
) 0,4/0,7 kgf/cm
2
Test pressure (75% of minimum static pressure) . . . . . . . . . . . . . . . 31 kPa (4.5 lbf/in
2
) 0,32 kgf/cm
2
Fuel lift pump - Six cylinder engines
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.C.Delco, type LU
Method of drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eccentric on camshaft of engine
Static pressure (no delivery) . . . . . . . . . . . . . . . . . . . . . . 34,5/55,2 kPa (5/8 lbf/in
2
) 0,35/0,56 kgf/cm
2
Test pressure (75% of minimum static pressure) . . . . . . . . . . . . . . . 26 kPa (3.75 lbf/in
2
) 0,26 kgf/cm
2
Fuel filter
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Twin parallel flow or single element
Fuel lift pump - AE, YE - four and six cylinder engines
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bosch, FP/KG24MW304
Method of drive . . . . . . . . . . . . Eccentric on camshaft of engine or on camshaft of fuel injection pump
Fuel filter
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Twin parallel flow or single element
20A.22 Perkins Phaser/1000 Series, April 1995