FUEL SYSTEM 20A
5 Loosen the union nut (A1) at the fuelled starting
aid, if one is fitted, and operate the priming lever of
the fuel lift pump until fuel, free of air, comes from
the connection. Tighten the union nut at the starting
aid.
6 Loosen the high-pressure pipe connections (B1)
at two of the atomisers.
7 Ensure that the manual stop control, if one is
fitted, is in the "run" position. Operate the starter
motor until fuel, free from air, comes from the pipe
connections.
8 The engine is now ready to start.
Note: If the engine runs correctly for a short time
and then stops or runs roughly, check for air in the
fuel system. If there is air in the fuel system, there
is probably a leakage in the suction or low-pressure
system.