20E FUEL SYSTEM
5 Put the electrical system switch to the "ON"
position. Operate the starter motor until fuel, free
from air, comes from the pipe connections. Tighten
the high-pressure pipe connections to 22 Nm
(16 lbf ft) 2,2 kgf m. Return the switch to the "OFF"
position.
6 The engine is now ready to start.
If the engine runs correctly for a short time and
then stops or runs roughly, check for air in the fuel
system. If there is air in the fuel system, there is
probablely a leakage in the low pressure system.