24C AUXILIARY EQUIPMENT
Exhauster
To remove and to fit24C-01
To remove
1 Disconnect the lubricating oil and vacuum pipes
from the exhauster and fit covers to the open ends
of the pipes.
2 Release the setscrews and remove the
exhauster.
To fit
1 Ensure that the joint faces of the exhauster and
the timing case are clean and renew the joint. Fit
the exhauster to the timing case and tighten the
setscrews.
2 Remove the covers from the open ends of the
pipes and connect the oil pipe and the vacuum pipe
to the exhauster.
24C.02 Perkins Phaser/1000 Series, April 1995