CYLINDER HEAD ASSEMBLY 12
Valve guides
Inside diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,51/9,56 mm (0.3744/0.3764 in)
Outside diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15,90/15,91 mm (0.6260/0.6265 in)
Interference fit of valve guide in cylinder head . . . . . . . . . . . . . . . . . . 0,03/0,07 mm (0.0012/0.0027 in)
Full length:
- Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57,94 mm (2.281 in)
- Exhaust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61,10 mm (2.406 in)
Protrusion from bottom of recess for valve spring . . . . . . . . . . . . . . . . . . . . . . . . 15,10 mm (0.594 in)
Double valve springs - outer
Fitted length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35,8 mm (1.41 in)
Load at fitted length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176/195 N (39.5/43.7 lbf) 18/20 kgf
Number of active coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6
Number of damper coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Direction of coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Left hand - damper coil to cylinder head
Double valve springs - inner
Fitted length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34,0 mm (1.34 in)
Load at fitted length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89/104 N (20/23 lbf) 9/11 kgf
Number of active coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9
Number of damper coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Direction of coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Right hand - damper coil to cylinder head
Single valve springs
Fitted length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40,0 mm (1.57 in)
Load at fitted length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312/344 N (70.1/77.3 lbf) 31,8/35,1 kgf
Number of active coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5
Number of damper coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Direction of coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Left hand
Perkins Phaser/1000 Series, April 1995 12A.27