CAN Controllers and Acceptance Filter 198 May 03, 2004
Philips Semiconductors Preliminary User Manual
LPC2119/2129/2292/2294ARM-based Microcontroller
4, 12, 20 RS These bits are identical to the RS bit in the GSR. 0 0
5, 13, 21
TS1,
TS2,
TS3
1: The CAN Controller is transmitting a message from this Tx Buffer. 0 0
6, 14, 22 ES These bits are identical to the ES bit in the GSR. 0 0
7, 15, 23 BS These bits are identical to the BS bit in the GSR. 0 0
Table 132: CAN Status Register (CANSR - 0xE00x x01C)
CANSR Name Function Reset Value RM Set