Real Time Clock 250 May 03, 2004
Philips Semiconductors Preliminary User Manual
LPC2119/2129/2194/2292/2294ARM-based Microcontroller
Consolidated Time Register 2 (CTIME2 - 0xE002401C)
The Consolidate Time Register 2 contains just the Day of Year value.
Table 185: Consolidated Time Register 2 Bits (CTIME2 - 0xE002401C)
CTIME2 Function Description
11:0 Day of Year Day of year value in the range of 1 to 365 (366 for leap years).
31:12 Reserved
Reserved, user software should not write ones to reserved bits. The value read from a reserved
bit is not defined.