Relay outputs 750330 751330
Utilisation category of safety con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 4 A 4 A
Max. power 1000 VA 1000 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 4 A 4 A
Max. power 100 W 100 W
Utilisation category of auxiliary con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 4 A 4 A
Max. power 1000 VA 1000 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 4 A 4 A
Max. power 100 W 100 W
Utilisation category
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Utilisation category of safety con-
tacts
AC15 at 230 V 230 V
Max. current 3 A 3 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 4 A 4 A
Utilisation category of auxiliary con-
tacts
AC15 at 230 V 230 V
Max. current 3 A 3 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 4 A 4 A
Utilisation category in accordance
with UL
Voltage 240 V AC G.U. (same polarity) 240 V AC G.U. (same polarity)
With current 4 A 4 A
Voltage 24 V DC G. U. 24 V DC G. U.
With current 4 A 4 A