Display menu - Configuration
Operating Manual PNOZ s30
1001715-EN-19
| 72
Level Designation
on the display
Description Settings
Rotary encoder + pnp proximity switch
} TTL + pnp proximity switch *
– TTL diff. (A, /A, B, /B), Z Freq Inipnp
(Z)
– TTL single (A, B), Z Freq Inipnp (Z)
} HTL + pnp proximity switch *
– HTL diff. (A, /A, B, /B), Z Freq Inipnp
(Z)
– HTL single (A, B),Z Freq Inipnp (Z)
} sin/cos 1 Vss + pnp proximity switch *
– sin/cos 1 Vss (A, /A, B, /B), Z Freq
Inipnp (Z)
} Hiperface + pnp proximity switch *
– Hiperface (A, /A, B, /B), Z Freq Inipnp
(Z)
* Alternatively, a track from an HTL encoder
can also be used instead of a pnp proximity
switch
The configuration is the same as with the
pnp proximity switch as Z-frequency monit-
oring.
2 Track AB Settings for tracks A and B
3 AB Direction
Default:
Normal
Select direction for tracks A and
B Information:
This function is used to display
a forward movement as positive
linear/rotational speed, irre-
spective of the installation of the
rotary encoder.
} Normal
} Inverted
3 Track AB fmax
Default:
10mHz
Enter max. frequency of the en-
coder on tracks A and B
Important:
The frequency must be less
than or equal to the max. en-
coder frequency specified in the
encoder's data sheet and less
than the max. speed of the
monitored drive.
10 mHz … 1.00 MHz