Replacing a Power Supply
VessRAID 1740s
The power supply on the VessRAID 1740s is not replaceable onsite. If you need
to replace the power supply, contact Technical Support and make arrangements
to return the subsystem to Promise for service. See page 291.
VessRAID 1840s
The redundant power supplies on the VessRAID 1840s are designed as field-
replaceable units. You can replace a power supply without removing the
VessRAID from the rack.
Removing the old power supply
To remove the power supply:
1. Verify that the power supply LED is amber or red.
2. Switch off the power to the power supply you plan to replace.
3. Unplug the power cord.
4. Loosen and remove the retaining screw on the left side of the power supply.
5. Pull the power supply out of the VessRAID enclosure.
Installing the new power supply
To install the power supply:
1. Carefully slide the power supply into the enclosure.
2. Install and tighten the retaining screw on the left side of the power supply.
3. Plug in the power cord.
4. Switch on the power supply.
5. Verify that the new power supply LED is green.
This completes the power supply replacement procedure.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VessRAID 1740s and is the answer not in the manual?

Promise Technology VessRAID 1740s Specifications

General IconGeneral
BrandPromise Technology
ModelVessRAID 1740s
CategoryNetwork Storage Server
LanguageEnglish

Related product manuals