Chapter 5: Management with the CLU
179
Restarting the Subsystem
There are two methods for shutting down the subsystem, depending on your
connection. Choose the applicable procedure:
• Restarting the Subsystem (page 179)
• Restarting VessRAID – Serial Connection (page 179)
Restarting VessRAID – Telnet Connection
This function enables you to restart the VessRAID subsystem on a Telnet
connection. You can only do part of this procedure in the CLU. Additional action is
required, as described below.
To restart the VessRAID:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Shutdown or Restart and press Enter.
3. Highlight Option and press the spacebar to display Restart.
4. Highlight Submit and press Enter.
A warning message appears.
5. Press Y to continue.
The screen goes blank.
6. Wait for no less than two minutes.
7. Re-establish your Telnet connection to the VessRAID CLU.
If you cannot re-establish a connection, wait 30 seconds, then try again.
Restarting VessRAID – Serial Connection
This function enables you to restart the VessRAID subsystem on a serial
connection. You can only do part of this procedure in the CLU. Additional action is
required, as described below.
To restart the VessRAID:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Shutdown or Restart and press Enter.
3. Highlight Option and press the spacebar to display Restart.
4. Highlight Submit and press Enter.
A warning message appears.
5. Press Y to continue.
The screen will display shutdown and startup functions.