4. Click OK in the confirmation box.
Changing the Startup Setting
1. Under Startup Type:
• Click the Automatic option to start the service automatically during
system startup. Recommended.
• Click the Manual option to start the service manually (the service does
not start during system startup).
2. Click the Submit button.
Stopping SNMP service
To stop the SNMP service:
1. Click the Stop button.
2. Click OK in the confirmation box.
Starting or Restarting SNMP service
To start or restart the SNMP service, click the Start or Restart button.
Making Netsend Settings
VessRAID’s Netsend service sends VessRAID subsystem events in the form of
text messages to your Host PC and other networked PCs. This service is
normally Stopped and set to Manual start. See “Netsend Requirements” on
page 75.
To change the Netsend settings:
1. Click the Subsystem icon in Tree View.
2. Click the Administrative Tools icon.
3. Click the Netsend link.
4. Click the Start button to start the Netsend service.
5. Click the Submit button.
Adding Netsend recipients
See “Netsend Requirements” on page 75. To add a Netsent recipient:
1. In the Recipient Address field, type the IP address of the recipient PC.
2. Under Recipient filter, choose the lowest level of Severity to be reported for
each event.
See “Setting-up User Event Subscriptions” on page 59 for an explanation of
the Severity levels.
3. Click the Update button to add the new recipient to the list
4. Click the Submit button.