Chapter 5: Management with the CLU
177
Shutting Down the Subsystem
There are two methods for shutting down the subsystem, depending on your
connection. Choose the applicable procedure:
• Shutting down the VessRAID – Telnet Connection (page 177)
• Shutting down the VessRAID – Serial Connection (page 177)
Shutting down the VessRAID – Telnet Connection
This function enables you to shutdown the VessRAID subsystem on a Telnet
connection. You can only do part of this procedure in the CLU. Additional action is
required, as described below.
To shutdown the VessRAID:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Shutdown or Restart and press Enter.
3. Highlight Shutdown or Restart and press Enter.
4. Highlight Option and press the spacebar to display Restart.
5. Highlight Submit and press Enter.
A warning message appears.
6. Press Y to continue.
The screen goes blank.
7. Wait for no less than two minutes.
8. Manually turn off the power supply switch (both switches on the 1840s
model) on the back of the subsystem.
Shutting down the VessRAID – Serial Connection
This function enables you to shutdown the VessRAID subsystem on a serial
connection. You can only do part of this procedure in the CLU. Additional action is
required, as described below.
To shutdown the VessRAID:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Shutdown or Restart and press Enter.
Caution
After you turn the power supply switches off, you must wait at least
10 seconds before you turn the power switches on again.