EasyManua.ls Logo

Promise Technology VessRAID 1740s - Page 254

Promise Technology VessRAID 1740s
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VessRAID 1740s, 1840s Product Manual
240
RAID 1
A RAID 1 Source logical drive can migrate to the following Target logical drives:
RAID 1E
A RAID 1E Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 None.
RAID 1E 3 or more physical drives.
Add 1 or more physical drives.
RAID 5 3 physical drives minimum, 16 maximum.
RAID 1 must have less than 16 physical drives.
Add 1 or more physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
Add 2 or more physical drives.
RAID 50 6 physical drives minimum, 16 per axle maximum.
Add 4 or more physical drives.
Target Requirements
RAID 0 None.
RAID 1E Add physical drives.
RAID 5 3 physical drives minimum, 16 maximum.
RAID 1E must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 50 6 physical drives minimum, 16 per axle maximum.

Table of Contents

Related product manuals