Chapter 9: Troubleshooting
267
Host-interface controller
has encountered an
unrecoverable error
Restart the VessRAID. See page 81 (WebPAM
PROe) or page 179 (CLU).
Host-interface controller
has received an abort-
task/ abort task set/clear
task set command.
Result of user action. Normal.
Host-interface controller
has received an clear
ACA command.
Result of clearing an auto contingent alliance
condition. If this message appears repeatedly,
contact Technical Support. See page 291.
Host-interface controller
has received a LUN reset
command.
Result of user action. Normal.
Host-interface controller
has received a bus reboot
The VessRAID rebooted itself. If this message
appears repeatedly, contact Technical Support. See
page 291.
Host-interface controller
has encountered an
unknown error
An unidentified error occurred. If this message
appears repeatedly, contact Technical Support. See
page 291.
Host-interface controller
has encountered a
system error
A VessRAID system error occurred. If this message
appears repeatedly, contact Technical Support. See
page 291.
Host-interface controller
has encountered a fatal
error
Restart the VessRAID. See page 81 (WebPAM
PROe) or page 179 (CLU). If this message appears
repeatedly, contact Technical Support. See page 291.
Host-interface controller
settings have changed
Result of user action. Normal.
Logical Drive
Logical drive initialization
has started
Result of user action. Normal.
Logical drive initialization
has completed
Logical drive is ready to use. Normal.
Logical drive initialization
has paused
Initialization paused because of user intervention,
schedule or a higher priority background activity.
Logical drive initialization
has resumed
Initialization has resumed again after a pause.
Reported Event Corrective Action

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VessRAID 1740s and is the answer not in the manual?

Promise Technology VessRAID 1740s Specifications

General IconGeneral
BrandPromise Technology
ModelVessRAID 1740s
CategoryNetwork Storage Server
LanguageEnglish

Related product manuals