Chapter 9: Troubleshooting
273
Rebuild is resumed Rebuild has resumed again after a pause.
Rebuild is stopped Rebuild stopped because of user intervention,
schedule or the logical drive was deleted or the target
disk drive encountered an error.
If rebuild stopped by the user, restart the rebuild. See
page 107 (WebPAM PROe) or page 146 (CLU).
Rebuild stopped internally The logical drive is offline. See page 276.
Rebuild is aborted due to
an internal error.
System resources are low. Reduce system load or
restart the VessRAID. See page 81 (WebPAM PROe)
or page 179 (CLU).
Rebuild is queued Rebuild has been set manually or by schedule.
Rebuild marks logical
drive synchronized upon
rebuild completion
Result of successful rebuild. Normal.
Redundancy Check
Redundancy Check is
started
Redundancy Check has started manually or by
schedule.
Redundancy Check is
completed
Redundancy Check has finished.
Redundancy Check is
paused
Redundancy Check paused because of user
intervention, schedule or a higher priority background
activity.
Redundancy Check is
resumed
Redundancy Check has resumed again after a
pause.
Redundancy Check is
stopped
Redundancy Check stopped because of user
intervention, schedule or the logical drive was deleted
or went critical or offline. See page 276.
Redundancy Check is
aborted due to internal
error
System resources are low. Reduce system load or
restart the VessRAID. See page 81 (WebPAM PROe)
or page 179 (CLU).
Redundancy Check
encountered inconsistent
block(s)
Check the logical drive’s inconsistent block table. See
page 115. Rebuild the disk array if necessary. See
page 98 (WebPAM PROe) or page 140 (CLU).
Redundancy Check task
is queued
Redundancy Check has been set manually or by
schedule.
Redundancy Check task
is stopped internally
The logical drive is offline. See page 276.
Reported Event Corrective Action

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VessRAID 1740s and is the answer not in the manual?

Promise Technology VessRAID 1740s Specifications

General IconGeneral
BrandPromise Technology
ModelVessRAID 1740s
CategoryNetwork Storage Server
LanguageEnglish

Related product manuals