EasyManuals Logo

Promise Technology VessRAID 1740s User Manual

Promise Technology VessRAID 1740s
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #295 background imageLoading...
Page #295 background image
Chapter 9: Troubleshooting
281
You can set the VessRAID to migrate disk arrays under Non-Volatile Random
Access Memory (NVRAM), a much faster process because it writes data to the
memory in the controller. However, if a physical drive or the controller fails during
migration, the logical drives will go offline and you will lose data. See “Incomplete
Array” on page 279.
Because the setting for migration under NVRAM requires special access, most
users will not encounter this condition.
Physical Drive Fails during Transport
Transport is the action of moving the physical drives of a disk array:
To different slots in the same VessRAID enclosure
From one VessRAID enclosure to another
If a physical drive fails during a transport, or you do not move all of the physical
drives to their new locations, WebPAM PROe will display an incomplete array.
See “Incomplete Array” on page 279.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VessRAID 1740s and is the answer not in the manual?

Promise Technology VessRAID 1740s Specifications

General IconGeneral
BrandPromise Technology
ModelVessRAID 1740s
CategoryNetwork Storage Server
LanguageEnglish

Related product manuals